Fleck 5600 Multi-Port Control Valve


Product Description

FLECK 5600 Control Valve

Model:Fleck 5600 
1. Simple mechanical design is easy to use

2. Two valve body designs: one for downflow regeneration and one for upflow (covers every valve in the 5600 family - quick access to all internal components)

3.Injector/drain modules containing the brine valve, flow controls, and injector are removable from the valve's exterior

4.Ruggedly-built timer is designed with heavy-duty 3/8" wide plastic gears

5. 5600 controls are user-friendly and easily programmable

6. Non-corrosive, UV-resistant, fiber-reinforced polymer valve body

7. Choice of 7 or 12 day clock or demand regeneration with a mechanical meter

8. Economical - small annual power consumption; keeps the time and activates the piston/valve mechanics with a single motor

9. Designed with double backwash

Mechanical Residential Control Valve
Features:
1.Simple mechanical design is easy to use
2.Injector/drain modules containing the brine valve, flow controls, and injector are removable from the valve's exterior.
3.Ruggedly-built timer is designed with heavy-duty 3/8"wide plastic gears
4.5600 controls are user-friendly and easily programmable.
5.Non-corrosive, UV-resistant, fiber-reinforced polymer valve body
6.Choice of 7 or 12 day clock or demand regeneration with a mechanical meter
7.Low water use piston and economical - small annual power consumption; keeps the time and activates the piston/valve mechanics with a single motor
8.Designed with double backwash Options
Options
9.Bypass control valve (BCV)( Noryl or Nonleaded brass)
10.It can be used for backwash filter valves.
11.Up-flow regeneration
12.35 days disk controller
13.ow water use piston (uses as little as0.11./regeneration).
14.Meter-initiated regeneration
15.Auxiliary switch
Valve Specifications
Valve material
Noryl
Inlet/Outlet pipe diameter
3/4″,1″, 1-1/4″
Regenerative process
More than 6 cycles
Range of flow(0.35MPa Inflow pressure)
Continuous water inflow (0.1MPa drop)
4.54m3/h
Peak water inflow (0.175MPa drop)
5.9m3/h
Cv
5.0
Back-wash flow (0.175MPa drop)
1.59m3/h
Regeneration
Down/Up flow
Both are suitable
Program regulation
Adjustable cycles Brine fill only
Maximum regenerative time
180 minutes per cycle
Meter
Accuracy
0.057-3.4m3/h±5%
Capacity options
Standard:0.47-8m3
Extended:2.3-40m3
Main size
Central line diameter
0.8125″/1.05″O.D.
Drain line diameter
1/2″NPTF
Brine line diameter
1600-3/8″
Base diameter
2-1/2″-8NPSM
Height from top of tank
7″
Suited base diameter
(Soften) 6″——12″
Expect filter 6″—10″
Additional Information
Regenerative system
1610
Electrical rating
24V,110V,220V-50,60Hz
Maximum power
3W
Estimated shipping weight
Time clock:5 Ibs
Metered valve:6 Ibs
Pressure
Designed:2.1MPa Operating:0.14-0.84MPa
Operating Temperature
34°-110°F(10°-43°C)
It has been proved as safe drinking water device material.
 

 